Ground–structure interaction

Design

The interaction between soil (ground) and structure consists of an exchange of mutual stress between the structure itself and the foundations ground. This means that the movement of the whole ground-structure system is influenced by the type of ground as well as by the type of structure. The main types of foundations, based upon several building characteristics, are:

The filing of foundations grounds takes place according to the mechanical properties of the grounds themselves: in Italy, for instance, according to the new earthquake-proof norm – Ordinanza 3274/2003 – you can identify the following categories:

The type of foundations is selected according to the type of ground; for instance, in the case of homogeneous rock formations connected plinths are selected, while in the case of very low quality grounds plates are chosen.

For further information about the various ways of building foundations see foundation (architecture).

Both grounds and structures can be more or less deformable; their combination can or cannot cause the amplification of the seismic effects on the structure. Ground, in fact, is a filter with respect to all the main seismic waves, as stiffer soil fosters high-frequency seismic waves while less compact soil accommodates lower frequency waves. Therefore, a stiff building, characterized by a high fundamental frequency, suffers amplified damage when built on stiff ground and then subjected to higher frequencies.

For instance, suppose there are two buildings that share the same high stiffness. They stand on two different soil types: the first, stiff and rockythe second, sandy and deformable. If subjected to the same seismic event, the building on the stiff ground suffers greater damage.

The second interaction effect, tied to mechanical properties of soil, is about the lowering (sinking) of foundations, worsened by the seismic event itself, especially about less compact grounds. This phenomenon is called soil liquefaction.

Mitigation

The methods most used to mitigate the problem of the ground-structure interaction consist of the employment of the before-seen isolation systems and of some ground brace techniques, which are adopted above all on the low-quality ones (categories D and E). The most diffused techniques are the jet-grouting technique and the pile work technique. The jet-grouting technique consists of injecting in the subsoil some liquid concrete by means of a drill. When this concrete hardens it forms a sort of column that consolidates the surrounding soil. This process is repeated on all areas of the structure. The pile work technique consists of using piles, which, once inserted in the ground, support the foundation and the building above, by moving the loads or the weights towards soil layers that are deeper and therefore more compact and movement-resistant.

External links

This article is issued from Wikipedia - version of the 5/5/2016. The text is available under the Creative Commons Attribution/Share Alike but additional terms may apply for the media files.