Artificial pancreas

The artificial pancreas is a technology in development to help people with diabetes automatically control their blood glucose level by providing the substitute endocrine functionality of a healthy pancreas.

There are several important exocrine (digestive) and endocrine (hormonal) functions of the pancreas, but it is the lack of insulin production which is the motivation to develop a substitute. While the current state of insulin replacement therapy is appreciated for its life-saving capability, the task of manually managing the blood sugar level with insulin alone is arduous and inadequate.

The goal of the artificial pancreas is two-fold:

  1. to improve insulin replacement therapy until glycemic control is practically normal as evident by the avoidance of the complications of hyperglycemia, and
  2. to ease the burden of therapy for the insulin-dependent.

Different approaches under consideration include:

Approaches

Bioengineering

The Bio-artificial pancreas: this diagram shows a cross section of bio-engineered tissue with encapsulated islet cells which deliver endocrine hormones in response to glucose.

A biological approach to the artificial pancreas is to implant bioengineered tissue containing islet cells, which would secrete the amount of insulin, amylin, and glucagon needed in response to sensed glucose.

When islet cells have been transplanted via the Edmonton protocol, insulin production (and glycemic control) was restored at the expense of immunosuppression. Encapsulation of the islet cells in a protective coating has been developed to block the immune response to transplanted cells, which relieves the burden of immunosuppression and benefits the longevity of the transplant.[1]

One concept of the bio-artificial pancreas uses encapsulated islet cells to build an islet sheet which can be surgically implanted to function as an artificial pancreas.[2]

This islet sheet design consists of:

Islet sheet research is pressing forward with large animal studies at the present, with plans for human clinical trials within a few years.

Gene therapy

Gene therapy: Designing a viral vector to deliberately infect cells with DNA to carry on the viral production of insulin in response to the blood sugar level.

Technology for gene therapy is advancing rapidly such that there are multiple pathways possible to support endocrine function, with potential to practically cure diabetes.[3]

Medical equipment

Continuous blood glucose monitoring

Technology for continuous blood glucose monitoring supports the mission of the artificial pancreas by:

  1. automatically providing a blood glucose reading every few minutes without finger sticks from the user,
  2. monitoring trends pertaining to rising and falling blood sugars, which is helpful in the prediction of blood glucose levels in the immediate future,
  3. comparing blood sugar levels and predictions against a high blood sugar threshold, and then prompting the user that a correction bolus from an insulin pump is needed immediately,
  4. comparing blood sugar levels and predictions against a low blood sugar threshold, and then prompting the user to reduce the basal insulin from the pump or to eat something.

These capabilities suggest that a stream of real-time data can be used to "close the loop" and control the insulin pump directly.

Some issues with the present performance of continuous sensing technology suggest that additional study is needed for application to the artificial pancreas:

  1. continuous sensors require calibration a few times a day, by performing a manual blood glucose test with a finger stick, and then entering the blood glucose data into the continuous system for a sensor correction,
  2. continuous sensors are measuring interstitial glucose, so there is a time delay between the sensor data and the true blood glucose,
  3. automatic control removes the intellect of the user, which can be an additional safeguard when the data is subject to error and must be verified before taking action.

As the state of the art for blood glucose monitoring continues to advance, so does the promise of the artificial pancreas. A Closed-loop Artificial Pancreas regulating glucose through algorithms and by the way of coordinated glucose and insulin deliveries has been introduced recently in Japan by the Japanese Company Nikkiso.

Basal control

The medical equipment approach to an artificial pancreas: automatic control of an insulin pump with feedback from a continuous blood glucose sensor.

The first step in controlling an insulin pump based on continuous blood glucose data is to automatically control the basal rate of the insulin pump. When a bolus has not recently been performed, the pump can manage the blood glucose level by adjusting the basal rate as needed:

When controlling the basal rate alone, the closed loop can still correct a meal bolus error that was too large or small for the food consumed by:

First clinical tests

In France, a human clinical trial of an artificial pancreas is underway. The system is fully automated by combining Medtronic MiniMed's long-term glucose sensor and its implantable insulin pump.[7] A summary of the project shows promise as well as some present limitations:

Insulin and amylin combination

Main articles: amylin and pramlintide

When pramlintide (brand name Symlin or synthetic amylin) is used in combination with insulin, the benefits for post-prandial glycemic control are substantial.[8]

Pramlintide is a relatively new treatment for diabetes. The treatment involves:

Pramlintide can be infused using an insulin pump. At the present time, the mixing of pramlintide and insulin in the same cartridge is not an approved practice, so two infusion pumps are used simultaneously. Since insulin and amylin are co-secreted by the pancreatic beta cells in response to raising blood glucose levels, using pramlintide and insulin together more closely duplicates the function of the pancreas.

Symlin has potential to support the artificial pancreas project because:

Bolus control

The ability of the electronic controls of the infusion pump, particularly in the bolus shaping capability, suggests that the control algorithm may replicate the function of the healthy pancreas in a more copycat fashion. At present, the insulin bolus is a predictive dose based on what is about to be eaten, and then infused completely. Even with the benefit of the closed-loop control of the basal insulin, the standard bolus is still a "guess and then fix it later" approach. Compare to the pancreatic physiology, where insulin and amylin are released from the beta cells in pulses almost directly to the liver in response to the immediate blood glucose level. The natural release from the beta cells is a closed loop response to sensed glucose, and the shape of the insulin delivery is adaptable and appropriate to the food eaten and the body's present metabolic capability.

As technology for continuous blood glucose monitoring improves, the integrated components will support a typical application of control theory by employing the proportional, integral, and derivative control algorithm.[10] This will make it feasible to infuse an adaptive bolus that changes its shape and integral dose based on the measured performance of the bolus in progress, depending on:

  • the rate of glucose increase (i.e the derivative function would deliver more insulin for a rapid increase in blood sugar);
  • the peak of the glucose curve (i.e. the proportional function would deliver more insulin for a higher peak in the blood sugar); and
  • the duration of elevated glucose (i.e. the integral function would deliver more insulin for a long duration of high blood sugar).

The adaptive bolus could start with an assumption of a typical proportions and a bolus shape like the combination bolus. This could include:

  1. a prebolus of pramlintide (optional perhaps, but resolves issue with insulin timing)
  2. initiation of a combination bolus with the initial spike sized in proportion to the present blood glucose level and trends in the change of blood glucose level,
  3. modification to the square wave portion of the bolus, increasing or extending if blood sugar is increasing, and decreasing or limiting in duration when blood sugar is decreasing.

The benefits of an automatic bolus delivery might include:

Glucagon combination

The purpose of glucagon is to raise blood sugar, primarily by promoting release of stored glucose in the liver. Human glucagon has been synthesized by recombinant DNA technology and is available in a dry powder form in the glucagon rescue kit. Glucagon injection pens are also sometimes provided to diabetics in the UK along with insulin. This is useful for rescue of unconscious diabetics from a severe state of hypoglycemia.[11]

In healthy pancreatic function, glucagon production is initially suppressed by beta cell production of insulin and amylin when blood sugar is high, and then is later produced by low or falling blood sugar. The natural pancreatic function uses glucagon at the end of an insulin cycle to release glucose from the liver, with two advantages:

  1. to prevent low blood sugar, and
  2. to speed the overall insulin action by cancelling the insulin tail.[12]

If an artificial pancreas were to simulate the natural endocrine pancreas to the maximum extent, then insulin and amylin would be used at the beginning of an insulin cycle and glucagon would be used at the end of the insulin cycle. Research with diabetic pigs given insulin-glucagon combination via separate subcutaneous infusion pumps demonstrated closed loop control without incidence of hypoglycemia.[13] While the copycat endocrine function including glucagon seems desirable, the benefits relative to the cost and complexity of an artificial pancreas without glucagon are not yet known.

Initiatives around the globe

In the United States in 2006, JDRF (formerly the Juvenile Diabetes Research Foundation) launched a multi-year initiative to help accelerate the availability of an artificial pancreas to people with diabetes.[14] The overall goal of the Artificial Pancreas Project is to accelerate the development, regulatory approval, and acceptance of continuous glucose monitoring and artificial pancreas technology in the shortest possible timeframe. The long-term goal is for broad patient access and a thriving competitive market for these devices and products.

JDRF's role in quickening the development and availability of the Artificial Pancreas consists of funding research in order to look over the outcomes of patients using the Artificial Pancreas, keeping close contact with the Food and Drug Administration so that the standards of the patient are met, advocating for health care coverage of technologies such as the Artificial Pancreas and working to ensure clinical acceptance of technologies such as the Artificial Pancreas. In 2011, JDRF strongly urged the FDA before Congress and in a petition to issue clear and reasonable guidance for an artificial pancreas by December 2011.

United Kingdom charity Diabetes UK funded research projects aimed at further developing and testing an artificial pancreas device on adult patients with type 1 diabetes.

In 2010 the European Commission funded AP@home project started to develop an Artificial Pancreas (AP) for “at home” use. This should allow patients with diabetes to live close to normal life. One aim of the project is focussed on developing and testing an AP system which uses an off-the-shelf continuous glucose monitoring (CGM) system and insulin pump. In parallel a novel approach was developed which allows to monitor glucose and infuse insulin via the same port. The AP@home project has recently come to an end and results of a 12-week unsupervised free-living closed-loop clinical study have been published in the New England Journal of Medicine.[15]

Several companies are working on clinical acceptance, including Medtronic Diabetes (MiniMed), Johnson & Johnson (Animas) and Insulet. These companies have semi-automated closed-loop systems that check the glucose level using a CGM(Continuous Glucose Monitor), ask the user to confirm the reading with a blood glucose meter and finally suggest amounts of insulin delivery. Some companies are also involved in potentially adding a glucagon pump to these systems in an effort to avoid hypoglycemia. One such company, called Pancreum,[16] has recently won an award for its artificial pancreas design.[17]

Grassroots efforts to create and commercialize a fully automated artificial pancreas system have also arisen directly from patient advocates and the diabetes community.[18] Bigfoot Biomedical, a company founded by parents of children with T1D have created algorithms and are developing a closed loop device that monitor blood sugar and appropriately provide insulin.[19]

Researchers at Imperial College London are working on a Bio-Inspired Artificial Pancreas (BiAP). The device is worn externally and combines a continuous glucose monitor that reads the user’s interstitial fluid sugar level with an insulin pump that infuses the insulin into the body. A biologically-inspired microchip which uses an algorithm to combine the two, is enabling the research team to replicate the activity of the beta cells of the pancreas using integrated circuits on a silicon microchip. With this they have been able to deliver insulin profiles expected in a healthy pancreas.[20]

In 2014, researchers at Harvard University announced that they had discovered how to make huge quantities of insulin-producing pancreatic beta cells from human embryonic stem cells. They hoped that these cells would in future transplanted into diabetes patients, eliminating the need for manufactured insulin.[21]

Endocrine physiology

The pancreas (below the stomach and above the duodenum) releases endocrine hormones (insulin, amylin, and glucagon) into the portal vein, where it flows directly to the liver.
Main article: pancreas

The pancreas produces three hormones that are important to glycemic control:

Upon digestion of carbohydrates, glucose levels in the blood will begin to rise. As the blood and glucose flow into the pancreas, insulin and amylin are co-secreted by the pancreatic beta cells directly into the bloodstream in response to elevated blood glucose levels. In the presence of glucose these insulin responses are almost exclusively delivered in boluses every 4 to 6 minutes. Insulin causes blood glucose to be removed from the bloodstream and stored in the liver and muscle cells. As the blood sugar goes higher, additional insulin will bring the blood sugar back down in a classic negative feedback loop. As insulin is released from the beta cells, amylin is also released into the bloodstream. Amylin slows gastric emptying, and also inhibits the release of glucagon from the pancreatic alpha cells. The effect of amylin is to spread out the blood glucose peak after eating, reducing the quantity of insulin needed. As the blood sugar level comes back toward normal, the beta cells will stop spurting insulin and amylin. As the glucose level approaches a low mark, the pancreatic alpha cells will release glucagon directly into the bloodstream. Glucagon causes the liver to release stored glucose back into the bloodstream. Increased glucagon will increase blood glucose levels to produce a positive error in the negative feedback loop. Together, the three endocrine hormones work as a system to maintain the blood glucose level between high and low boundaries. By delivering the insulin in boluses as presented by a non-diabetic pancreas, the goal of an artificial pancreas can be achieved.

When the beta cell produces insulin from proinsulin, a connecting peptide (or C-peptide) is also manufactured and released into the bloodstream. Absence of C-peptide in the blood indicates that insulin has not been released from the pancreas, and this fact confirms the diagnosis of diabetes type 1. C-peptide was believed to be only a by-product of natural insulin production; however, recent studies suggest that C-peptide exerts beneficial therapeutic effects on diabetic nociceptive neuropathy.[22]

Ideally, to replicate the natural function of the pancreas as closely as possible, an artificial pancreas might someday replace all of the beneficial endocrine functions lost, including the delivery of insulin, amylin, glucagon, and C-peptide.

Insulin therapy

The Insulin pump is used to automatically deliver basal insulin continuously, and bolus insulin at meal times by pressing the buttons. Before meals, a blood glucose value is entered into the pump to calculate the correction bolus to bring the blood glucose level back to the target value.

In insulin-dependent persons, blood glucose levels have been roughly controlled using insulin alone. The number of grams of carbohydrate is estimated by measuring foods, and the measurement is used to determine the amount of insulin necessary to cover the meal. The calculation is based on a simple open-loop model: an insulin to carbohydrate ratio (adjusted based on past success) is multiplied by the grams of carbohydrate to calculate the units of insulin needed. That quantity of insulin is then adjusted based on a pre-meal blood glucose measurement (insulin bolus increased for a high blood sugar or insulin bolus delayed and reduced for a low blood sugar). Insulin is injected or infused under the skin, and enters the bloodstream in approximately 15 minutes. After the insulin has acted in the bloodstream, the blood glucose level can be tested again and then adjusted with injection of more insulin, or eating more carbohydrates, until balance is restored. Assuming the design requirement is to truly mimic normal pancreatic delivery of insulin to the liver in order to achieve proper hepatic stimulation, and to cause normal insulin induced functions, until another system is available to deliver portal vein concentrations of insulin, an intravenous infusion device will be needed.

There are notable differences with insulin replacement compared to the function of pancreatic insulin delivery:

  1. the insulin dose is predicted based on measured food (where accuracy of measured carbohydrate is difficult) whereas pancreatic insulin is released in proportional response to actual blood glucose levels;
  2. pancreatic insulin is released into to the portal vein, where it flows almost directly to the liver, which is the major organ for storing glycogen (50% of insulin produced is used by the liver);
  3. pancreatic insulin is pulsatile which helps maintain the insulin sensitivity of hepatic tissues;
  4. injected insulin is delivered subcutaneously (under the skin) but not directly to the bloodstream, so there is a delay before injected insulin begins to reduce blood glucose (although this can be compensated by injecting insulin 15 minutes before eating);
  5. insulin which is not delivered intravenously cannot achieve normal momentary concentrations in the portal vein which connects the pancreas to the liver;
  6. replacement insulin therapy does not include amylin (although Symlin is now available for use), which can reduce the insulin need by 50%;
  7. replacement insulin is dosed as a best compromise between aggressive use for lowering the blood sugar when eating but also conservative use to avoid a post-prandial low blood sugar due to excess insulin, whereas pancreatic function releases insulin aggressively and later includes automatic release of glucagon at the end of an insulin cycle to manage the blood sugar level and avoid hypoglycemia.

An insulin pump to infuse a rapid-acting insulin is the first step in simulating the function of the pancreas. The pump can accurately deliver small increments of insulin compared to an injection, and its electronic controls permit shaping a bolus over time to match the insulin profile required for a given situation. The insulin pump is controlled by the pump user to bolus manually based on a recent blood glucose measurement and an estimate of the grams of carbohydrate consumed. This predictive approach is said to be open-loop. Once a bolus has been calculated and delivered, the pump continues to deliver its basal rate insulin in the manner that has been programmed into the pump controls based on the predicted insulin requirements of its user.

While insulin replacement is appreciated as a life saving therapy, its practical use in controlling blood glucose levels sufficiently to avoid the long-term complications associated with hyperglycemia is not ideal. Also, it is generally agreed that even with very tight glucose control, there are a significant number of patients who go on to develop all of the life impacting complications of diabetes. Thus, the goal of the Artificial Pancreas should be to normalize carbohydrate and lipid metabolism at a minimum.

References

  1. Cerco Medical: Science: Methods
  2. Cerco Medical: Company: Islet Sheet Research Archived September 1, 2006, at the Wayback Machine.
  3. Gene Therapy Approaches to Diabetes
  4. Mary Ann Liebert, Inc. - Cookie absent
  5. http://www.hopkinsbayview.org/healthcarenews06/060605diabetes.html
  6. Engene Inc
  7. Artificial Pancreas Information on MedicineNet.com
  8. Amylin replacement with pramlintide as an adjunct ...[Diabet Med. 2004] - PubMed Result
  9. SYMLIN.com - Home
  10. http://www.journalofdst.org/pdf/REVIEW/VOL-1-1-REV1-KLONOFF.pdf[]
  11. 4 Archived August 31, 2006, at the Wayback Machine.
  12. Glucagon
  13. "Glucagon May Add Another Dimension to Artificial Pancreas", JDRF Research Frontline, March 2007, pp 1-2. Archived October 16, 2007, at the Wayback Machine.
  14. Artificial Pancreas Project : JDRF
  15. Arnolds, Dr. Sabine. "The longest at-home free-living closed-loop study so far!". Retrieved 2015-09-23.
  16. Pancreum website
  17. Pancreum - 2011 DiabetesMine Design Challenge Winner
  18. Hurley, Dan (24 December 2014) WIRED Magazine, Diabetes Patients Are Hacking Their Way Toward a Bionic Pancreas
  19. Knutson, Ryan (8 June 2015) The Wall Street Journal, Computer Experts Deliver Insulin to Diabetic Kids
  20. Giles, Sheldrick (28 January 2014). "Diabetes experts confident they can wipe out killer disease in 25 years". The Express. Retrieved 2 April 2014.
  21. Colen, B.D. (9 October 2014) Giant leap against diabetes The Harvard Gazette, Retrieved 24 November 2014
  22. C-Peptide Reverses Nociceptive Neuropathy in Type 1 Diabetes - Kamiya et al. 55 (12): 3581 - Diabetes
This article is issued from Wikipedia - version of the 11/17/2016. The text is available under the Creative Commons Attribution/Share Alike but additional terms may apply for the media files.